By Digital Inverter 200 W 400 W 800 W

by Digital Inverter 200 W, 400 W, 800 W Owner’s Guide XP_Digital_200-400-800.book Page i Wednesday, October 26, 2005 2:51 PM
xantrex.com/documents/power-inverters/xantrex-inverters-digital/xpower_200-400-800_digital(975-0176-01-01_rev-b).pdf

 

 DOWNLOAD | Find Similar

 


advertisement

 

 

 

Text Previews (text result may be not accurate)

Digital Inverter 200 W, 400 W, 800 W Owner’s Guide XP_Digital_200-400-800.book Page i Wednesday, October 26, 2005 2:51 PM About Xantrex Xantrex Technology Inc. is a world-leading supplier of advanced power electronics and controls with products from 50 watt mobile units to one MW utility-scale systems for wind, solar, batteries, fuel cells, microturbines, and backup power applications in both grid-connected and stand-alone systems. Xantrex products include inverters, battery chargers, programmable power supplies, and variable speed drives that convert, supply, control, clean, and distribute electrical power. Trademarks Digital Inverter 200 W, 400 W, 800 W is a trademark of Xantrex International. Xantrex is a registered trademark of Xantrex International. Other trademarks, registered trademarks, and product names are the property of their respective owners and are used herein for identification purposes only. Notice of Copyright Digital Inverter 200 W, 400 W, 800 W Owner’s Guide © October 2005 Xantrex International. All rights reserved. Disclaimer UNLESS SPECIFICALLY AGREED TO IN WRITING, XANTREX TECHNOLOGY INC. (“XANTREX”) (a)MAKES NO WARRANTY AS TO THE ACCURACY, SUFFICIENCY OR SUITABILITY OF ANY TECHNICAL OR OTHER INFORMATION PROVIDED IN ITS MANUALS OR OTHER DOCUMENTATION. (b)ASSUMES NO RESPONSIBILITY OR LIABILITY FOR LOSS OR DAMAGE, WHETHER DIRECT, INDIRECT, CONSEQUENTIAL OR INCIDENTAL, WHICH MIGHT ARISE OUT OF THE USE OF SUCH INFORMATION. THE USE OF ANY SUCH INFORMATION WILL BE ENTIRELY AT THE USER’S RISK. Date and Revision October 2005 Revision B Part Number 975-0176-01-01 Contact Information Telephone:1 360-925-5097 Fax:1 360-925-5143 Web:www.xantrex.com/support XP_Digital_200-400-800.book Page ii Wednesday, October 26, 2005 2:51 PM 1. Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 About This Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2. Important Safety Information. . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Warnings and Cautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3 Additional Safety Guidelines . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 3. Digital Inverter Features. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 AC (Front) Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 DC (Back) Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 Digital Display (Top) Panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Types of Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12 Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13 4. Connecting the Digital Inverter . . . . . . . . . . . . . . . . . . . . . . . . . 14 Choosing a Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14 Connecting for Loads Under 150 W . . . . . . . . . . . . . . . . . . . . . . 15 Connecting for Loads Over 150 W . . . . . . . . . . . . . . . . . . . . . . . 16 5. Operating the Digital Inverter . . . . . . . . . . . . . . . . . . . . . . . . . . 19 Operating Conditions and Guidelines . . . . . . . . . . . . . . . . . . . . . 19 Shutting the inverter off. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 Operating normal loads . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21 Operating loads with high surge requirements. . . . . . . . . . . . . 22 Contents XP_Digital_200-400-800.book Page iii Wednesday, October 26, 2005 2:51 PM 6. Maintaining Battery Condition . . . . . . . . . . . . . . . . . . . . . . . . . .24 7. Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26 Common Problems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Buzz in audio systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Television interference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27 Troubleshooting Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28 8. Specifications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .31 9. Warranty and Return. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 10. Other Xantrex Products. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39 XP_Digital_200-400-800.book Page iv Wednesday, October 26, 2005 2:51 PM 1Introduction Thank you for purchasing the XPower Digital Inverter 200 W, 400 W, 800 W. These Digital Inverters are part of a family of advanced high- performance power inverters from Xantrex, the leader in high frequency inverter design. Connected to the 12 volt outlet in your car, truck, boat, RV, or directly from a dedicated 12 V battery (400 and 800 W only), the Digital Inverter efficiently and reliably powers a wide variety of household AC products, such as portable stereos, laptop computers, TVs, VCRs, and other similar products. The Digital Inverter uses reliable solid state power electronics for years of safe, trouble-free operation and includes the following automatic features to ensure safe and trouble-free operation: Low battery alarm Low voltage shutdown High voltage shutdown Overload shutdown Overheating shutdown Short-circuit protection XP_Digital_200-400-800.book Page 1 Wednesday, October 26, 2005 2:51 PM About This Guide To get the best performance from your Digital Inverter, we recommend that you read this guide before connecting and using the Digital Inverter. Save this guide for future reference. This guide contains: Important safety information (page3) Digital Inverter features (page6) Instructions for connecting the inverter (page14) Operating guidelines (page19) Troubleshooting information (page26) Specifications (page31) Warranty and service information (page33) XP_Digital_200-400-800.book Page 2 Wednesday, October 26, 2005 2:51 PM 2Important Safety Information Misusing or incorrectly connecting the Digital Inverter 200 W, 400 W, 800 W may damage the equipment or create hazardous conditions for users. Read the following safety instructions and pay special attention to all Caution and Warning statements in the guide. Warnings identify conditions that may result in personal injury or loss of life. Cautions identify conditions or practices that may damage the unit or other equipment. Warnings and Cautions WARNING: Shock hazard Keep children away from the Digital Inverter inverter. The inverter generates the same potentially lethal AC power as a normal household wall outlet. Treat the outlet with respect! WARNING: Heated surface The Digital Inverter housing may become uncomfortably warm, reaching 140° F (60° C) under extended high power operation. Ensure that at least 2 inches (5 cm) of air surround the inverter. During operation, keep it away from materials that may be affected by high temperatures. XP_Digital_200-400-800.book Page 3 Wednesday, October 26, 2005 2:51 PM WARNING: Explosion hazard Do not use the Digital Inverter in the presence of flammable fumes or gases, such as in the bilge of a gasoline powered boat, or near propane tanks. Do not use the Digital Inverter in an enclosure containing automotive-type, lead-acid batteries. These batteries, unlike sealed batteries, vent explosive hydrogen gas, which can be ignited by sparks from electrical connections. WARNING: Crash hazard Vehicle drivers should not configure or troubleshoot the Digital Inverter while they are driving the vehicle. CAUTION: Output non-sinusoidal Some chargers for small nickel-cadmium batteries can be damaged if connected to the Digital Inverter. Do not use the inverter with the following appliances: Small battery-operated appliances like rechargeable flashlights, some rechargeable shavers, and night lights that are plugged directly into an AC receptacle to recharge. Battery chargers used in hand power tools. These chargers display a warning label stating that dangerous voltages are present at the charger battery terminals. XP_Digital_200-400-800.book Page 4 Wednesday, October 26, 2005 2:51 PM CAUTION Do not connect live AC power to the Digital Inverter’s AC outlets. The inverter will be damaged even if it is turned off. Do not connect any AC load that has its neutral conductor connected to ground to the Digital Inverter. XP_Digital_200-400-800.book Page 5 Wednesday, October 26, 2005 2:51 PM 3Digital Inverter Features This section describes the main features of the Digital Inverter. AC (Front) Panel Figure 1 shows the AC panel of the 200 W unit. Figure 1 AC Panel of 200 W unit An AC receptacle is located on one end of the 200 W unit. You can plug in 120 V appliances with a combined total continuous power consumption of 160 W or less when the inverter is turned on. CAUTION To prevent overheating, ensure that all the ventilation openings on the unit are kept clear. 160 W/1.4A Continuous XP_Digital_200-400-800.book Page 6 Wednesday, October 26, 2005 2:51 PM Figure 2 shows the AC panel of the 400 W unit, which is very similar to the 800 W unit. Two AC receptacles are located on one end of the 400 W unit and the 800 W unit. You can plug in 120 V appliances with a combined total continuous power consumption of 320 W (400 W unit) or 640 W (800 W unit) or less when the inverter is turned on. Figure 2 AC Panel of 400 W unit XP_Digital_200-400-800.book Page 7 Wednesday, October 26, 2005 2:51 PM DC (Back) Panel Figure 3 shows the DC panel of the 200 W unit. Use Table 1 to identify the function of items. Figure 4 shows the DC panel of the 800 W unit, which is very similar to the 400 W unit. Use Table 1 to identify the function of items. Figure 3 DC Panel of 200 W unit Figure 4 DC Panel of 800 W unit XP_Digital_200-400-800.book Page 8 Wednesday, October 26, 2005 2:51 PM Table 1 DC Panel Functions ItemFunction Fan and Ventilation Openings The cooling fan on the units are designed to operate only when output power is greater than approximately 80 W. When the inverter is turned on, the fan may operate momentarily. The ventilation openings should not be covered at any time while the inverter is operating. A) Positive and B) Negative Cabling Terminals Connect the ring terminals on the power cables to these terminals. To ensure correct polarity, red must be connected to red and black must be connected to black. XP_Digital_200-400-800.book Page 9 Wednesday, October 26, 2005 2:51 PM Digital Display (Top) Panel Figure 5 shows the Digital Display panel. Use Table 2 to identify the function of items. Figure 5 Digital Display Panel XP_Digital_200-400-800.book Page 10 Wednesday, October 26, 2005 2:51 PM Table 2 Digital Display Panel Functions ItemFunction 1Switch to turn the unit on and off. Press to toggle the display function to show input voltage, output power and output voltage. Normal Operation Digital display shows input voltage, output power and output voltage. Error Mode Digital display shows error codes and alarm sounds when unit has shut down due to under-voltage, over-voltage, over-load, overheating or high-surge. 3LEDs indicate the status of the digital display. Audible Alarm An audible alarm warns you if an under-voltage shutdown is about to occur. XP_Digital_200-400-800.book Page 11 Wednesday, October 26, 2005 2:51 PM Types of Connections ProductLighter Plug Connection Cable Clamps/Battery Connections 200 W unitAvailable – You must connect a separate lighter plug cable (included). Not Available 400 W unitAvailable – You must connect a separate lighter plug cable (included). Available – You must connect a separate battery clamp cable (included). 800 W unitNot AvailableAvailable – You must connect a separate battery clamp cable (included). XP_Digital_200-400-800.book Page 12 Wednesday, October 26, 2005 2:51 PM Accessories Figure 6 shows the lighter plug cable that is included with the 200 W unit and 400 W unit. Figure 7 shows the cable supplied with the 400 W unit and 800 W unit for direct connection to a 12 V battery. Figure 6 Lighter Plug Cable Figure 7 Cable for Direct Connection to a 12 V Battery XP_Digital_200-400-800.book Page 13 Wednesday, October 26, 2005 2:51 PM 4Connecting the Digital Inverter It is recommended that you hard wire the 800 W unit directly to the 12V battery. Choosing a Location For best performance, place the inverter on a flat surface in a location that is: CAUTION The Digital Inverter must only be connected to a battery that has a nominal output of 12 V. It will not operate if connected to a 6 V battery and may be damaged if connected to a battery with 16 V or more. Dry Do not expose the inverter to water, rain, snow or spray. Cool XP_Digital_200-400-800.book Page 14 Wednesday, October 26, 2005 2:51 PM Connecting for Loads Under 150 W Follow these steps to connect the 200 W unit or 400 W unit: 1.Place the inverter on a flat surface such as the floor of your vehicle. 2.Make sure that the unit is off by verifying the digital display is off. 3.Take the power cord equipped with the lighter plug (Figure 6) and place the ring terminals over the two cabling terminals on the back of the inverter. (The cabling terminals are shown in Figure 3 and Figure 4.) 4.Fasten the positive (red) clamp to the positive battery post, and then fasten the negative (black) clamp to the negative battery post. CAUTION: Reverse polarity Power connections of the 12 V DC battery to the Digital Inverter must be positive to positive and negative to negative. A reverse polarity connection (positive to negative) will blow a fuse in the inverter and may permanently damage the unit. Damage caused by a reverse polarity connection is not covered by your warranty. CAUTION Make sure you connect red to red and black to black, and make sure you screw the nuts on tightly. XP_Digital_200-400-800.book Page 15 Wednesday, October 26, 2005 2:51 PM 5.Tighten the nut on each DC terminal until it is snug. Do not over-tighten. 6.Place the inverter’s lighter plug in the vehicle’s lighter socket or a 12 V outlet. 7.Turn on the unit by holding the switch located on top of the unit until 888 is shown on the display. The digital display will show the battery voltage, indicating that the Digital Inverter is operating normally and AC power is available at the outlet. 8.Plug in the AC product you want to operate. When not in use always turn the inverter off by holding the switch until the digital display turns off. Connecting for Loads Over 150 W You must connect the 400 W unit or 800 W unit directly to a 12 V battery if you are going to operate loads greater than 150 W continuously. When the inverter is connected this way, you can operate loads of any size up to 320 W continuously with a 400 W unit and 640W continuously with a 800 W unit. XP_Digital_200-400-800.book Page 16 Wednesday, October 26, 2005 2:51 PM Follow these steps to make a direct battery connection: 1.Place the inverter on a flat surface. 2.Make sure that the unit is off by verifying the digital display is off. 3.Take the cables equipped with battery clamps on one end (Figure 7) and place the ring terminals over the two cabling terminals on the back of the inverter. (The cabling terminals are shown in Figure 3 and Figure 4.) WARNING: Shock hazard Batteries contain corrosive materials and present an electrical shock hazard. To prevent irritation and burns, wear protective eyewear and clothing when you install the inverter or work with the batteries. Take special care to ensure that metal tools and personal metal objects like CAUTION: Reverse polarity Power connections of the 12 V DC battery to the Digital Inverter must be positive to positive and negative to negative. A reverse polarity connection (positive to negative) will blow a fuse in the inverter and may permanently damage the unit. Damage caused by a reverse polarity connection is not covered by your warranty. XP_Digital_200-400-800.book Page 17 Wednesday, October 26, 2005 2:51 PM 4.Fasten the positive (red) clamp to the positive battery post, and then fasten the negative (black) clamp to the negative battery post. 5.Turn on the unit by holding the switch located on top of the unit until 888 is shown on the display. The digital display will show the battery voltage, indicating that the Digital Inverter is operating normally and AC power is available at the outlet. 6.Plug in the AC appliance you want to operate. When not in use, always turn the inverter off by holding the switch until the digital display turns off. CAUTION Make sure you connect red to red and black to black, and make sure you screw the nuts on tightly. XP_Digital_200-400-800.book Page 18 Wednesday, October 26, 2005 2:51 PM 5Operating the Digital Inverter This section explains how to operate the Digital Inverter most efficiently. Operating Conditions and Guidelines This section describes normal operation as well as conditions that trigger an alarm or automatically shut down the Digital Inverter. Normal Operation When you connect the inverter to the vehicle’s lighter socket or directly to a 12 V battery and turn on the unit, the digital display will show input voltage, the input voltage LED illuminates and AC power is available at the outlets. You can now plug in your AC products and turn them on one at a time. Low Battery Alarm and Shutdown As the battery discharges, its voltage decreases. When the Digital Inverter senses that the voltage at its DC input has dropped to 11.0 V, it sounds an alarm, giving you time to shut down sensitive loads such as computers. If you ignore the alarm, and the DC input voltage drops below 10.5 V, the inverter shuts down all loads to save the battery from further discharge. The under-voltage error code ‘E01’ will show on the digital display. XP_Digital_200-400-800.book Page 19 Wednesday, October 26, 2005 2:51 PM High-input Voltage Shutdown If a defective battery charging system causes the battery voltage to rise to dangerously high levels, the Digital Inverter shuts down automatically. The over-voltage error code ‘E02’ will show on the digital display. Overload Shutdown If you connect an AC load that is rated too high (see Table 3) or a load that draws excessive surge power, the Digital Inverter shuts down. The overload error code ‘E03’ will show on the digital display. Overheating Shutdown The Digital Inverter shuts down automatically if it exceeds its safe operating temperature. The overheating error code ‘E04’ will show on the digital display. Shutting the inverter off If you are going to disconnect the battery, turn the inverter off first. Turn the inverter off by holding the switch until the display turns off. XP_Digital_200-400-800.book Page 20 Wednesday, October 26, 2005 2:51 PM Operating normal loads The Digital Inverter is capable of continuously powering most 120 V AC products with the following power rating maximums: The inverter’s AC (“modified sine wave”) output waveform is designed to function similarly to the sine wave shape of utility power. Most AC products correctly rated for the power rating maximums listed in Table 3 or less will operate normally with the Digital Inverter. Table 3 Power and Surge Ratings Product 5 min Max. Power Rating Continuous Power Rating Surge Rating Max. 200 W unit200 W160 W400 W 400 W unit400 W320 W700 W 800 W unit750 W640 W1200 W XP_Digital_200-400-800.book Page 21 Wednesday, October 26, 2005 2:51 PM Operating loads with high surge requirements The power, or wattage rating, of AC loads is the average amount of power they use. Some appliances consume more power than their power rating when they are first turned on. TVs, monitors, and electric motors are some products that have high surge requirements at start up. The Digital Inverter can supply momentary surge power that is higher than its maximum power rating. Some products rated less than power rating maximum for your inverter may exceed its surge capability and trigger an overload shutdown. If this problem occurs when attempting to operate several AC products at the same time, try first turning on the inverter with all AC products turned off, then one by one turn each on, starting with the high-surge product first. XP_Digital_200-400-800.book Page 22 Wednesday, October 26, 2005 2:51 PM Table 4 Wattage of Common AC Products Product a.Power requirements for product examples are estimates only. To calculate the wattage of a product, use the following equation: amperage x 115. Watts b.If you want to power two or more products simultaneously, add the power requirements of both prod- ucts to determine the total wattage. 200 W unit400 W unit800 W unit Cell phone/camcorder charger 10YesYesYes Video game console20YesYesYes Portable work light25YesYesYes Stereo system50YesYesYes Laptop computer75YesYesYes 13" TV100YesYesYes 27" TV200YesYes 20" TV/VCR combo300YesYes Small appliances400+Yes Power tools400+Yes XP_Digital_200-400-800.book Page 23 Wednesday, October 26, 2005 2:51 PM 6Maintaining Battery Condition The battery operating time of the Digital Inverter depends on the charge level of the battery, battery capacity, and the amount of power drawn by the AC loads you are operating. With a typical vehicle battery, you can expect the following: Table 5 Battery Operating Times InverterLoadSample ApplianceOperating Time 200 W unit50 WCD player6–8 hours 400 W unit100 Wsmall TV3–4 hours 800 W unit200 WTV/VCR1–2 hours XP_Digital_200-400-800.book Page 24 Wednesday, October 26, 2005 2:51 PM Here are some guidelines that will help to preserve your battery: Vehicle batteries are not designed for repeated deep-discharge cycles, and constantly recharging a vehicle’s battery will shorten its life. Therefore, when you are using a vehicle battery as a power source, start the vehicle every hour or two to recharge the battery. The Digital Inverter will operate while the engine is running, but the voltage drop that occurs when the engine starts may trigger a low-voltage shutdown. Vehicle batteries are designed to provide brief periods of very high current needed for engine starting. They are not intended for constant deep discharge. Regularly operating the Digital Inverter from a vehicle battery until the low-voltage alarm sounds will shorten the life of the battery. Consider connecting the Digital Inverter to a separate deep discharge-type battery if you will be frequently running electrical products for extended periods of time. If you are not going to use the Digital Inverter for a few days, turn off the unit. The inverter draws 0.4 A or less when the unit is on and no load is connected, but it will eventually discharge the battery. XP_Digital_200-400-800.book Page 25 Wednesday, October 26, 2005 2:51 PM 7Troubleshooting This section will help you identify the source of most problems that can occur with the Digital Inverter. If you have a problem with the inverter, please review this section before contacting your dealer. If you are unable to solve a problem and need to contact service, please prepare for the call by writing down the following details: Inverter’s serial number How long the inverter has been in use Where it is installed Appliances operating when the problem occurred A brief description of the problem XP_Digital_200-400-800.book Page 26 Wednesday, October 26, 2005 2:51 PM Common Problems Buzz in audio systems Some inexpensive stereo systems have inadequate internal power supply filtering and buzz slightly when powered by the Digital Inverter. The best solution is to use an audio system with a high-quality filter. Television interference The Digital Inverter is shielded to minimize interference with TV signals. If TV signals are weak, you may see interference in the form of lines scrolling across the screen. Try one of these suggestions to minimize or eliminate the problem: Adjust the orientation of the Digital Inverter, television, antenna, and cables. Maximize TV signal strength by using a better antenna, and use shielded antenna cable where possible. Try a different TV. Different models vary considerably in their susceptibility to interference. WARNING: Electrical shock and burn hazard Do not disassemble the Digital Inverter. It does not contain any user- serviceable parts. Attempting to service the inverter yourself could result in an electrical shock or burn. XP_Digital_200-400-800.book Page 27 Wednesday, October 26, 2005 2:51 PM Troubleshooting Reference This section describes problems, their symptoms, possible causes, and solutions. Problem: The AC load will not operate. Digital display is off. Problem: The inverter will run some small loads, but not larger ones. Possible CauseSolution Battery is defective.Check battery and replace if required. The inverter has been connected with reverse DC input polarity. Check connection to battery. The inverter has likely been damaged and needs to be repaired. Have the unit repaired (not covered under warranty). Loose cable connections.Check cables and connections. Tighten as required. Possible CauseSolution Voltage drop across DC cables.Shorten cables or use heavier cables. XP_Digital_200-400-800.book Page 28 Wednesday, October 26, 2005 2:51 PM Problem: Measured inverter output is too low. Problem: Battery run time is less than expected. Possible CauseSolution A standard “average-reading” AC voltmeter has been used to measure output voltage, resulting in an apparent reading 5–15 V too low. For accurate measurement, the Digital Inverter modified sine wave output requires a “true RMS” voltmeter for accurate measurements. The battery voltage is too low.Recharge the battery. Possible Cause Solution The AC product power consumption is higher than rated. Use a larger battery to make up for the increased power requirement. The battery is old or defective.Replace the battery. The battery is not being charged properly. Some chargers are not able to fully recharge a battery. Make sure that you use a powerful charger. Power dissipation in DC cables.Use shorter/heavier DC cables. XP_Digital_200-400-800.book Page 29 Wednesday, October 26, 2005 2:51 PM Problem: The AC load will not operate, error code shows on digital display and alarm is sounding. ErrorPossible CauseSolution E01Low voltage shutdown because battery is discharged. Recharge battery. Shorten cables or use heavier cables. E02Over-voltage shutdown because of high input voltage. Verify the charging system is properly regulated and the battery is 12 V nominal. E03The AC product(s) connected are rated at more than the inverter’s continuous power rating; overload shutdown has occurred. Use a product with a power rating within the inverter’s continuous power rating (see Table 3). E04The inverter has overheated due to poor ventilation. Overheating shutdown has occurred. Turn inverter off and allow to cool for 15 minutes. Clear blocked fan or remove objects covering unit. Move the inverter to a cooler place. Reduce load if continuous operation is required. E05The AC products connected have a surge power that exceeds the Digital Inverter’s surge capability or the AC products connected are short-circuited and shutdown has occurred. The products exceed the inverter’s surge capability. Use a product with a starting surge power within the Digital Inverter’s capability. XP_Digital_200-400-800.book Page 30 Wednesday, October 26, 2005 2:51 PM 8Specifications Specifications are subject to change without notice. 200 W unit400 W unit800 W unit AC output voltage (nominal)120 V AC DC input voltage range10.5–15.5 V DC Maximum continuous AC output power 160 W 320 W 640 W 5 minutes AC output power200 W400 W750 W Maximum AC output surge power 400 W 700 W 1200 W AC output frequency 60 ± 1 Hz AC output waveformModified Sine Wave No load current draw (at 12 V input) 0.3 A 0.3 A 0.4 A Efficiency (maximum)90% Ambient operating temperature range 0–40 °C32–104 °F Storage temperature-20–60 °C-4–140 °F XP_Digital_200-400-800.book Page 31 Wednesday, October 26, 2005 2:51 PM 200 W unit400 W unit800 W unit Low voltage alarm Low voltage shutdown High voltage shutdown 11.0V 10.5V 15.5V 11.0V 10.5V 15.5V 11.0V 10.5V 15.5V Dimensions (L × W × H) 102 × 84 × 51 mm 4 × 3 × 2" 137 × 102 × 51 mm 5 × 4 × 2" 141 × 114 × 61 mm 7 × 4 × 2" Weight 10oz (0.28 kg)1 lb (0.44 kg)1 lb 13 oz (0.82 kg) a.Provides maximum 800 watts of AC output power for up to 1 minute. 1 --- XP_Digital_200-400-800.book Page 32 Wednesday, October 26, 2005 2:51 PM 9Warranty and Return Warranty What does this warranty cover? This Limited Warranty is provided by Xantrex Technology Inc. ("Xantrex") and covers defects in workmanship and materials in your Digital Inverter 200 W, 400 W, 800 W. This warranty period lasts for six (6) months from the date of purchase at the point of sale to you, the original end user customer. You require proof of purchase to make warranty claims. What will Xantrex do? Xantrex will, at its option, repair or replace the defective product free of charge, provided that you notify Xantrex of the product defect within the Warranty Period, and provided that Xantrex through inspection establishes the existence of such a defect and that it is covered by this Limited Warranty. Xantrex will, at its option, use new and/or reconditioned parts in performing warranty repair and building replacement products. Xantrex reserves the right to use parts or products of original or improved design in the repair or replacement. If Xantrex repairs or replaces a product, its warranty continues for the remaining portion of the original Warranty Period or 90 days from the date of the return shipment to the customer, whichever is greater. All replaced products and all parts removed from repaired products become the property of Xantrex. Xantrex covers both parts and labor necessary to repair the product, and return shipment to the customer via a Xantrex-selected non-expedited surface freight within the contiguous United States and Canada. Alaska and Hawaii are XP_Digital_200-400-800.book Page 33 Wednesday, October 26, 2005 2:51 PM How do you get service? If your product requires troubleshooting or warranty service, contact your dealer. If you are unable to contact your dealer, or the dealer is unable to provide service, contact Xantrex directly at: Direct returns may be performed according to the Xantrex Return Material Authorization Policy described in your product manual. For some products, Xantrex maintains a network of regional Authorized Service Centers. Call Xantrex or check our website to see if your product can be repaired at one of these facilities. What proof of purchase is required? In any warranty claim, dated proof of purchase must accompany the product and the product must not have been disassembled or modified without prior written authorization by Xantrex. Proof of purchase may be in any one of the following forms: The dated purchase receipt from the original purchase of the product at point of sale to the end user, or The dated dealer invoice or purchase receipt showing original equipment manufacturer (OEM) status, or The dated invoice or purchase receipt showing the product exchanged under warranty Telephone:1 360-925-5097 Fax:1 360-925-5143 Web:www.xantrex.com/support XP_Digital_200-400-800.book Page 34 Wednesday, October 26, 2005 2:51 PM What does this warranty not cover? This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal, installation, or troubleshooting of the customer's electrical systems. This warranty does not apply to and Xantrex will not be responsible for any defect in or damage to: a)the product if it has been misused, neglected, improperly installed, physi- cally damaged or altered, either internally or externally, or damaged from improper use or use in an unsuitable environment; b)the product if it has been subjected to fire, water, generalized corrosion, biological infestations, or input voltage that creates operating conditions beyond the maximum or minimum limits listed in the Xantrex product specifications including high input voltage from generators and lightning strikes; c)the product if repairs have been done to it other than by Xantrex or its authorized service centers (hereafter "ASCs"); d)the product if it is used as a component part of a product expressly war- ranted by another manufacturer; e)the product if its original identification (trade-mark, serial number) mark- ings have been defaced, altered, or removed. Disclaimer Product THIS LIMITED WARRANTY IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED BY XANTREX IN CONNECTION WITH YOUR XANTREX PRODUCT AND IS, WHERE PERMITTED BY LAW, IN LIEU OF ALL OTHER WARRANTIES, CONDITIONS, GUARANTEES, REPRESENTATIONS, OBLIGATIONS AND LIABILITIES, EXPRESS OR IMPLIED, STATUTORY OR OTHERWISE IN XP_Digital_200-400-800.book Page 35 Wednesday, October 26, 2005 2:51 PM CONNECTION WITH THE PRODUCT, HOWEVER ARISING (WHETHER BY CONTRACT, TORT, NEGLIGENCE, PRINCIPLES OF MANUFACTURER'S LIABILITY, OPERATION OF LAW, CONDUCT, STATEMENT OR OTHERWISE), INCLUDING WITHOUT RESTRICTION ANY IMPLIED WARRANTY OR CONDITION OF QUALITY, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE TO THE EXTENT REQUIRED UNDER APPLICABLE LAW TO APPLY TO THE PRODUCT SHALL BE LIMITED IN DURATION TO THE PERIOD STIPULATED UNDER THIS LIMITED WARRANTY. IN NO EVENT WILL XANTREX BE LIABLE FOR ANY SPECIAL, INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES, LOSSES, COSTS OR EXPENSES HOWEVER ARISING WHETHER IN CONTRACT OR TORT INCLUDING WITHOUT RESTRICTION ANY ECONOMIC LOSSES OF ANY KIND, ANY LOSS OR DAMAGE TO PROPERTY, ANY PERSONAL INJURY, ANY DAMAGE OR INJURY ARISING FROM OR AS A RESULT OF MISUSE OR ABUSE, OR THE INCORRECT INSTALLATION, INTEGRATION OR OPERATION OF THE PRODUCT. Exclusions If this product is a consumer product, federal law does not allow an exclusion of implied warranties. To the extent you are entitled to implied warranties under federal law, to the extent permitted by applicable law they are limited to the duration of this Limited Warranty. Some states and provinces do not allow limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential XP_Digital_200-400-800.book Page 36 Wednesday, October 26, 2005 2:51 PM damages, so the above limitation(s) or exclusion(s) may not apply to you. This Limited Warranty gives you specific legal rights. You may have other rights which may vary from state to state or province to province. Warning: Limitations On Use Please refer to your product manual for limitations on uses of the product. SPECIFICALLY, PLEASE NOTE THAT THE IGITAL NVERTER 200 W, 400 W, 800 W SHOULD NOT BE USED IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES. WITHOUT LIMITING THE GENERALITY OF THE FOREGOING, XANTREX MAKES NO REPRESENTATIONS OR WARRANTIES REGARDING THE USE OF THE XANTREX IGITAL NVERTER 200 W, 400 W, 800 W IN CONNECTION WITH LIFE SUPPORT SYSTEMS OR OTHER MEDICAL EQUIPMENT OR DEVICES. Return Material Authorization Policy XP_Digital_200-400-800.book Page 37 Wednesday, October 26, 2005 2:51 PM When you contact Xantrex to obtain service, please have your instruction manual ready for reference and be prepared to supply: The serial number of your product Information about the installation and use of the unit Information about the failure and/or reason for the return A copy of your dated proof of purchase XP_Digital_200-400-800.book Page 38 Wednesday, October 26, 2005 2:51 PM Return Procedure 1.Package the unit safely, preferably using the original box and packing materials. Please ensure that your product is shipped fully insured in the original packaging or equivalent. This warranty will not apply where the product is damaged due to improper packaging. 2.Include the following: The RMA number supplied by Xantrex Technology Inc. clearly marked on the outside of the box. A return address where the unit can be shipped. Post office boxes are not acceptable. A contact telephone number where you can be reached during work hours. A brief description of the problem. 3.Ship the unit prepaid to the address provided by your Xantrex customer service representative. If you are returning a product from outside of the USA or Canada In addition to the above, you MUST include return freight funds and are fully responsible for all documents, duties, tariffs, and deposits. If you are returning a product to a Xantrex Authorized Service Center (ASC) XP_Digital_200-400-800.book Page 39 Wednesday, October 26, 2005 2:51 PM Out of Warranty Service If the warranty period for your Digital Inverter 200 W, 400 W, 800 W has expired, if the unit was damaged by misuse or incorrect installation, if other conditions of the warranty have not been met, or if no dated proof of purchase is available, your unit may be serviced or replaced for a flat fee. To return your Digital Inverter 200 W, 400 W, 800 W for out of warranty service, contact Xantrex Customer Service for a Return Material Authorization (RMA) number and follow the other steps outlined in “Return Procedure” on page39. Payment options such as credit card or money order will be explained by the Customer Service Representative. In cases where the minimum flat fee does not apply, as with incomplete units or units with excessive damage, an additional fee will be charged. If applicable, you will be contacted by Customer Service once your unit has been received. 10Other Xantrex Products To see the range of inverters and chargers offered by Xantrex, visit our web site at www.xantrex.com XP_Digital_200-400-800.book Page 40 Wednesday, October 26, 2005 2:51 PM