GROWMATE 1200 800 600

micro grow greenhouse systems, inc 26111 ynez rd., suite c-4, temecula, ca 92591 phone (909)-296-3340 fax (909)-296-3350 revision 1.2, 01-24-02
igcusa.com/catalogs/ventmatep-manual.pdf

 

 DOWNLOAD | Find Similar

 


advertisement

 

 

 

Text Previews (text result may be not accurate)

26111 YNEZ RD., SUITE C-4, TEMECULA, CA 92591 PHONE (909)-296-3340 FAX (909)-296-3350 Revision 1.2, 01-24-02 INSTALLATION PROCEDURES GROWMASTER, GROWMATE PLUS, AND VENTMATE PLUS PANEL MOUNTING Mount the control panel in an accessible location. Make sure that the location is free of vibration and in close proximity to the devices being controlled. Always consider voltage drop of electrical current when locating the control panel. Securely mount the panel. SWITCHING CONTACTORS AND RELAYS The control panel will operate the greenhouse equipment by way of load contactors and load relays . ALL RELAYS AND LOAD CONTACTORS USED MUST HAVE A SURGE SUPPRESSOR INSTALLED ACROSS THE COIL OF THE RELAY OR LOAD CONTACTOR These surge suppressors are readily available from Micro Grow Greenhouse Systems, Inc. All load contactors and relays are also readily available from Micro Grow Greenhouse Systems, Inc. To decide which to use, follow this guide: LOAD CONTACTORS Exhaust fans, pad pumps, horizontal air flow fans, heating pumps, fan jets, large heaters, crop lighting, and all other larger electrical loads over 1/6 H.P. LOAD RELAYS: Signal switching such as the small control lines for gas fired heaters, control lines for vent and shade system controls, small loads such as motorized shutters, other loads up to 1/6 H.P. CUSTOM CONTACTOR AND RELAY PANEL AVAILABLE A custom-built load contactor and load relay panel is available from Micro Grow Greenhouse Systems, Inc. This panel will contain all the required switching apparatus for your project, as well as a correctly sized machine tool transformer. Contact Micro Grow Greenhouse Systems, Inc. for pricing and availability. TRANSFORMERS A 24 VAC transformer will power the control panel. It is most important to use a MACHINE TOOL TYPE. A Machine Tool Transformer is a heavy-duty variety that will allow for high inrush currents that are associated with the use of load contactors and relays. Micro Grow Greenhouse Systems, Inc. stocks these types of transformers. Use no smaller than a 50 VA Machine Tool Transformer. For a system that has more than three load contactors connected, use a 100 VA Machine Tool Transformer. ELECTRICAL CIRCUITS The electrical circuit that feeds the machine tool transformer must have no other loads connected to it. This will prevent damaging surges from other related electrical devices. Follow all local and national codes in the connection of all the greenhouse equipment. Always allow for voltage drop conditions. Always consider that the greenhouse is a wet environment. Always follow the code rulings for disconnect switches and overcurrent devices on greenhouse equipment. USE A QUALIFIED AND LICENSED ELECTRICIAN AT ALL TIMES. WIRING METHODS Always use stranded wire when connecting cables or conductors to the actual circuit board of the control panel. This will allow flexibility. Use no smaller than #18 gauge-stranded wire for all outputs. Use no smaller than the recommended wire size of stranded cable for inputs, generally #22 gauge. Route sensor conductors separately from control conductors. This is very important so as to reduce electrical interference. Never route sensor conductors in conduits used for other voltages. This is in violation of the electrical code and will cause dangerous interference to the control system. Always locate the actual sensor in the center of the range that is being controlled for accurate readings. Do not allow the sensor to come in contact with any greenhouse structure member such as a post that would give off any radiated heat and cause a false temperature reading. Do not locate the sensor where a particular piece of equipment would cause false readings, such as a heater blowing directly on the sensor. If using a weather station, mount the wind/rain sensor is a clear area, free of any wind obstructions. Route all control conductors separately from sensor conductors. This is very important so as to reduce electrical interference. Control conductors maybe routed in conduits that contain other power system wiring only if the insulation material on the conductors is the same as the power system wiring. Consult the national electrical code or local codes if in doubt about the insulation ratings of the wire in use. Remember; always use a qualified and licensed electrician. VENT SYSTEMS, SHADE SYSTEMS, ROLL UP CURTAINS When connecting a vent system, shade system, or roll up curtain ventilation system to the control panel, you must use a separate control box designed for that particular vent or shade system. These are readily available from Micro Grow Greenhouse Systems, Inc. Generally these separate control boxes feature overcurrent protection for the particular motor on the vent or shade system, provisions for direct limit switch connections, and a manual means of operating the vent or shade system independent of the main control system. These separate control boxes will connect the main control system either directly through the outputs of the control system, or they will require control relays for interconnection to the main control system. PROGRAMMING SWITCHES There are two main programming switches located on the Ventmate Plus front panel. These are: RUN-SET SWITCH VENTILATION` TEMPERATURES. 1. Continue to toggle the The control system allows for customization of temperature separations and differentials CRO GROW GREENHOUSE SYSTEMS, NC. 26111 Ynez Road, Sui Temecul CA Phone 909. 296. 3340 Fax 296. awn byDat but orOr der VENTMATE PLUS FRONT PANEL GH01/ 02N/ AN/ VENTMATE SET RUN ONOFF LOW CURRENT VENT A CLOSE VENT A OPEN AUTO GHT DAY THE CURRENT TEMPERATURE, AND THE GHEST AND LOWEST READI NG DURI THE LAST 24 HOURS. THE CURRENT VENT EASY FRONT PANEL TOGGLE SWI TCHES FOR PROGRAMMI AND CALI BRATI ON. VENTI LATI ON AND HEATI TEMPERATURES FOR DAY AND NI GHT SETTI NGS, OPTI ONAL DEHUMI FY, PANEL MOUNTED SWI TCH TO SELECT THE MODE OF OPERATION. THE PARTI CULAR LL SHOW ANY STAGE I OPERATION, EI THER MANUAL OR AUTOMATI THE DI SPLAY WI LL ALTERNATE BETWEEN CALI BRATI ON AND MODE SELECTI ONS GHTED STATUS I NDI CATORS EACH OUTPUT HAS A FRONT MODE VENT B CLOSE VENT B OPEN HEATI NG 1 DEHUMI HEATI NG 2 RCULATI RUN VENT A VENT B HEATI DEHUMI SET MODE/ CLOCK CALI BRATE SET UP VENT MANUALLY OPERATED, OR LEFT I N THE AUTOMATI OUTPUT MAY BE LEFT OFF, POSI ON OF OPERATI ON. POSI ON, TI ME OF DAY AND MODE I PROGRAMMI NG OF SEPARATE STATUS LI GHTS FOR EASY ALSO DI SPLAYED. ARE FEATURED. awn 3 DEGREES #3 OFF #4 ON MMEDI ATE SHI PMENT OF ALL REQUI RED CONNECTI ON DEVI CES AND ACCESSORI ES. CRO GROW GREENHOUSE SYSTEMS. SEE YOUR DI STRI BUTOR OR CALL MI CRO GROW FOR GREENHOUSE SYSTEMS. 50 AND 100 VA MACHI NE TOOL TRANSFORMERS ARE AVAI LABLE FROM ALL CORRECT LOAD CONTACTORS AND CONTROL RELAYS ARE AVAI LABLE FROM MI CRO GROW PROTECTI ON DEVI NSTALLED ACROSS THE COI LS. SURGE SUPPRESSI ON DEVI CES ARE ALL CONNECTED 24 VAC LOAD RELAYS AND CONTACTORS MUST HAVE A SURGE CRO GROW GREENHOUSE SYSTEMS, NC. Phone 3340 Fax VENTMATE PLUS FILE: VENTMATE PLUS INPUTS & OUTPUTS. DWG 01/ FACTORY DEFAULT SETTI NGS) FACTORY DEFAULT SETTI NGS) TURN OFF WHEN VENT A I TURN OFF WHEN VENT A I S OPEN Ynez Road, Sui Temecul CA VENT OPENS TO 100% VENT OPENS TO 95% #7 ON #7 OFF 4 DEGREES 1 DEGREE PAST STAGE 1 #5 ON #5 OFF #3 ON #4 ON #3 ON #4 OFF SUPPLI ED WI TH EACH UNI OUTPUT #3 OUTPUT #4 OUTPUT #5 OUTPUT #6 OUTPUT #7 OUTPUT #8 8 6 R CI RCULATI HEATI NG 1 HEATI NG 2 DEHUMI VENT B CLOSE VENT B OPEN P SWI TCH VENTMATE PLUS NPUTS OUTPUTS NOT EXCEED THI S OR DAMAGE MAY RESULT. DO NOT EXCEED 1 AMP USI NG A 100 VA TRANSFORMER OR 2 AMPS WHEN USI NG A 50 VA MPORTANT: DO NOT EXCEED 4 AMPS FOR THE FUSE RATI NG WHEN 2 AMPS TOTAL I F A 50 VA TRANSFORMER I N USE) FOR ANY SI NGLE OUTPUT OR 4 AMPS TOTAL FOR ALL OUTPUTS. P SWI TCH CONFI GURATI 2 DEGREES ( FACTORY DEFAULT) 2 DEGREES ( FACTORY DEFAULT) Dat but 1 DEGREES 4 DEGREES 3 DEGREES #1 ON #2 OFF #3 OFF #4 OFF #1 ON #2 ON #1 OFF #2 OFF #1 OFF #2 ON TRANSFORMER. USE A SLOW BLOW VARI THE CONTROL OUTPUTS ARE RATED AT 1 AMP EACH MAXI MUM. DO F A SMALLER SI ZED TRANSFORMER I S USED, ADJ UST THE FUSE USE A MACHI NE TOOL VARI ETY ONLY 100 VA I S RECOMMENDED. der PROTECTI ON ACCORDI NGLY. See f e not SENSOR TRANSFORMER OUTPUT #1 OUTPUT #2 24VAC POWER I NPUT 24VAC POWER I NPUT COM COM OUTPUT FUSED +5VDC SENSOR I NPUT TERMI NAL STRI COMMON COM COM POWER NPUT LOADS FOR ALL COMMON 24 VAC VENT A OPEN VENT A CLOSE OPTI ONAL HUMI R TEMPERATURE PHOTOCELL OVERRI DE 1 +5 VDC MACHI NE TOOL 24 VAC VENTMATE TEMPS HUMI TY SENSORS awn Phone 909. 296. Fax CRO GROW GREENHOUSE SYSTEMS, NC. Ynez Road, Sui Temecul CA 92591 ect der Dat but TEMPERATURE VENTMATE PLUS TO SENSOR TERMI NAL STRI SOI OR SENSOR COMMONBLACK RED CONTROLLED AREA, AT BENCH OR CROP LEVEL, GREENHOUSE METAL POSTS AND MEMBERS. AWAY FROM DI RECT CONTACT WI LOCATE SENSOR I N THE CENTER OF THE SENSOR COMMON R TEMPERATURE +5 VDC HUMI TYBLACK WHI GREEN CONTROLLED AREA, AT BENCH OR CROP LEVEL, GREENHOUSE METAL POSTS AND MEMBERS. AWAY FROM DI RECT CONTACT WI LOCATE SENSOR I N THE CENTER OF THE TEMPERATURE & HUMI OPTI ONAL STANDARD AI STRI TO SENSOR TERMI NAL SENSOR OPTI ONAL ASPI RATED AI LOCATE SENSOR I N THE CENTER OF THE AWAY FROM DI RECT CONTACT WI GREENHOUSE METAL POSTS AND MEMBERS. CONTROLLED AREA, AT BENCH OR CROP LEVEL, 24 VAC COMMON SENSOR COMMON R TEMPERATURE 24 VAC POWER ROUTE TO SENSOR I NPUT TERMI NALS +5 VDC HUMI TEMPERATURE AND HUMI WHI BLACK GREEN ORANGE OR BROWN BLUE SENSOR TRANSFORMER FROM SENSOR OPTI ONAL STANDARD HUMI TY SENSOR LOCATE SENSOR I N THE CENTER OF THE AWAY FROM DI RECT CONTACT WI GREENHOUSE METAL POSTS AND MEMBERS. CONTROLLED AREA, AT BENCH OR CROP LEVEL, SENSOR COMMON TERMI NAL TO SENSOR HUMI +5 VDC STRI GREEN BLACK SENSORS - PAGE 1 OF 2 OUTDOOR TEMPERATURE CRO GROW GREENHOUSE SYSTEMS, NC. Ynez Road, Sui Temecul CA 92591 Phone 3340 Fax 296. 3350 ect awn byDat but orOr der VENTMATE PLUS PHOTOCELL SENSOR GH01/ 02N/ AN/ SENSOR - PAGE 2 OF 2 SENSOR COMMONBLACK PHOTOCELLRED PHOTOCELL VENTMATE PLUS 1 . NORMALLY CLOSED TERMI NALS 5 . NORMALLY OPEN TERMI NALS 9 . COMMON TERMI NALS 13 . 24 VAC COI RELAY I S A DPDT OVERRI DE I NPUT SENSOR COMMON OVERRI DE I NPUT SUCH AS WEATHERMASTER OR 24 VAC FROM OVERRI DE DEVI WEATHERMATE. VENTMATE PLUS FILE: VENTMATE PLUS DIRECT OVERRI DE. DWG 01/ awn ect Phone Fax 3350 CRO GROW GREENHOUSE SYSTEMS, NC. Ynez Road, Sui Temecul CA 92591 but VENTMATE PLUS RECT OVERRI DE CONNECTI ONS Dat der RAIN SENSOR SENSOR OUTDOOR TEMP. SENSOR WIND SPEED 123+5VCOMDIP SWITCH 24 COM 24 COM STRIP OUTPUT POWER SENSOR INPUT STRIP WEATHERSTAT POWER INPUT STRIP FACTORY JUMPER DO NOT REMOVE DIP SWITCH SETTINGS The DIP swi ch can be used change he me del ays. Ref he Weat her manual TRANSFORMER VA MINIMUM RATING SENSOR COMMON +5 VDC RAIN WIND OUTDOOR TEMPERATURE WHT RED GRN BLK YEL +5VDC SENSOR INPUT POWER COM OUTPUT FUSED COM INPUT 1245 DIP SWITCH COMCOM WEATHERSTAT SENSOR RIGID GALVANIZED MOUNTING CONDUIT RAIN HEATERORG 24 VACBLU 24 VAC COMBRN 24 24 VAC COM RED BLACK 129 WIND/ RAIN OVERRIDE WIND VAC OUTPUT RAIN VAC OUTPUT 24 VAC COM SENSOR COMMON LOCATE SENSOR IN THE CENTER OF THE AWAY FROM DIRECT CONTACT WITH GREENHOUSE METAL POSTS AND MEMBERS. CONTROLLED AREA, AT BENCH CROP LEVEL, WIND RAIN OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT OUTPUT NOTE: THE OUTPUTS OF THE WEATHERSTAT MAY CONNECT DIRECTLY THE OVERRIDE INPUTS OF CONTROL SYSTEM CAPABLE ACCEPTING 24 VAC SIGNAL. IF OTHER SWITCHING IS DESIRED, THE OUTPUTS MAY BE CONNECTED THE COILS OF CONTROL RELAYS INTERRUPT THE AUTOMATIC OPERATION OF VENTS, RETRACTABLE ROOFS, LIMITED WARRANTY Micro Grow Greenhouse Systems, Inc. warrants that all of the products Micro Grow Greenhouse Systems, Inc. manufactures are free from defects at the time of shipment by Micro Grow Greenhouse Systems, Inc. This warranty covers defects in workmanship and materials. No warranty is extended on any parts, materials, or components manufactured by others and purchased by Micro Grow Greenhouse Systems, Inc., and any warranty on these materials is limited to the warranty supplied by the original manufacturer or supplier of said products only. This warranty excludes any and all damages cause by installation by unqualified individuals, damage by misuse or neglect, shipment damage, alterations to original manufacturing, and improper installation or use for any reason than intended by manufacturer. This warranty may not be altered in any manner except with the written authorization of one the officers or owners of Micro Grow Greenhouse Systems, Inc. The only and sole liability of Micro Grow Greenhouse Systems, Inc. under this warranty is limited to repairing, replacing or the issuance of credit for any products returned to Micro Grow Greenhouse Systems, Inc., during the warranty period of twelve (12) months from date of shipment. This warranty is specifically conditioned upon Micro Grow Greenhouse Systems, Inc. being notified in writing promptly upon discovery of any product defects by the buyer or end user. The product must then be returned prepaid to Micro Grow Greenhouse Systems, Inc. within the twelve month warranty period for inspection by Micro Grow Greenhouse Systems, Inc. Upon inspection of said product, Micro Grow Greenhouse Systems, Inc. will notify buyer or end user of its findings. At Micro Grow Greenhouse